Paper
19 March 2013 Achieving sub-pixel resolution using CZT-based photon counting detectors for dedicated breast CT
Andrey Makeev, John McGrath, Martin Clajus, Scott Snyder, Stephen J. Glick
Author Affiliations +
Proceedings Volume 8668, Medical Imaging 2013: Physics of Medical Imaging; 86680T (2013) https://doi.org/10.1117/12.2008351
Event: SPIE Medical Imaging, 2013, Lake Buena Vista (Orlando Area), Florida, United States
Abstract
Semiconductor based photon-counting detectors for x-ray CT have a number of advantages over energy integrat­ ing detectors, including reduced electronic and Swank noise, increased dynamic range, capability of spectral CT for material decomposition, and improved SNR characteristics through energy weighting. Quite a few clinical applications could benefit from high-resolution spectral CT. For example, in breast CT the visualization of mi­ crocalcifications and assessment of tumor microvasculature after contrast enhancement require spatial resolution on the order of 100 μm or better. A straightforward approach to increasing spatial resolution by decreasing the detector pixel size, leads to two major problems: 1) fabricating circuitry with small pixels becomes very costly, and 2) inter-pixel charge spreading can obviate any improvement in spatial resolution. In this study, we have used computer simulations to investigate position estimation algorithms that utilize charge sharing to achieve sub-pixel position resolution. To study these algorithms, we model a simple detector geometry with a pixellated 5 x 5 anode array, and use conditional probability functions modeling electron-hole charge transport in CZT. We used COMSOL Multiphysics software to map the distribution of charge pulses in the detector. Performance of two x-ray interaction position estimation algorithms were evaluated: 1) method of maximum likelihood, and 2) a fast, practical algorithm that can be realistically implemented in a readout ASIC, providing identification of the quadrant of the pixel in which interaction occurred. Both methods exhibit good sub-pixel resolution performance, however their actual efficiency is limited by electronic noise.
© (2013) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Andrey Makeev, John McGrath, Martin Clajus, Scott Snyder, and Stephen J. Glick "Achieving sub-pixel resolution using CZT-based photon counting detectors for dedicated breast CT", Proc. SPIE 8668, Medical Imaging 2013: Physics of Medical Imaging, 86680T (19 March 2013); https://doi.org/10.1117/12.2008351
Lens.org Logo
CITATIONS
Cited by 2 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Sensors

X-rays

Detection and tracking algorithms

Breast

Electrons

Semiconductors

X-ray detectors

Back to Top