Paper
15 March 2013 Automatic probe artifact detection in MRI-guided cryoablation
Xinyang Liu, Kemal Tuncali, William M. Wells III, Gary P. Zientara
Author Affiliations +
Abstract
Probe or needle artifact detection in 3D scans gives an approximate location for the tools inserted, and is thus crucial in assisting many image-guided procedures. Conventional needle localization algorithms often start with cropped images, where unwanted parts of raw scans are cropped either manually or by applying pre-defined masks. In cryoablation, however, the number of probes used, the placement and direction of probe insertion, and the portions of abdomen scanned differs significantly from case to case, and probes are often constantly being adjusted during the Probe Placement Phase. These features greatly reduce the practicality of approaches based on image cropping. In this work, we present a fully Automatic Probe Artifact Detection method, APAD, that works directly on uncropped raw MRI images, taken during the Probe Placement Phase in 3Tesla MRI-guided cryoablation. The key idea of our method is to first locate an initial 2D line strip within a slice of the MR image which approximates the position and direction of the 3D probes bundle, noting that cryoprobes or biopsy needles create a signal void (black) artifact in MRI with a bright cylindrical border. With the initial 2D line, standard approaches to detect line structures such as the 3D Hough Transform can be applied to quickly detect each probe’s axis. By comparing with manually labeled probes, the analysis of 5 patient treatment cases of kidney cryoablation with varying probe placements demonstrates that our algorithm combined with standard 3D line detection is an accurate and robust method to detect probe artifacts.
© (2013) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Xinyang Liu, Kemal Tuncali, William M. Wells III, and Gary P. Zientara "Automatic probe artifact detection in MRI-guided cryoablation", Proc. SPIE 8671, Medical Imaging 2013: Image-Guided Procedures, Robotic Interventions, and Modeling, 86712E (15 March 2013); https://doi.org/10.1117/12.2008530
Lens.org Logo
CITATIONS
Cited by 3 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Magnetic resonance imaging

3D image processing

Image segmentation

Kidney

Algorithm development

3D imaging standards

Binary data

Back to Top