Paper
24 June 2014 Experimental tomographic scanning (TOSCA) imagers
Author Affiliations +
Abstract
The tomographic scanner (TOSCA) detects signals using line detectors scanning a scene at regularly distributed angles. These line scan signals are then processed to reconstruct 2-dimensional images. In the simplest form, a 1-axis rotating conical scan optics scans across a simple patterned reticle, the signal collection being done with a single pixel detector. Experimental mono- and multispectral cameras using this approach are demonstrated under varying illumination conditions. Of particular interest is the TOSCA system’s ability to handle and compensate for light sources modulated with a frequency higher than that of the frame rate. We also demonstrate for the first time a TOSCA imager operating in the infrared region. The device is put together using 3D-printed key parts and low cost optical components, leading to a very economical infrared camera.
© (2014) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
H. Hovland "Experimental tomographic scanning (TOSCA) imagers", Proc. SPIE 9070, Infrared Technology and Applications XL, 90700H (24 June 2014); https://doi.org/10.1117/12.2050971
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Sensors

Reticles

Modulation

Cameras

Imaging systems

Signal detection

Mirrors

Back to Top