Paper
18 September 2014 Three-dimensional registration of synchrotron radiation-based micro-computed tomography images with advanced laboratory micro-computed tomography data from murine kidney casts
Peter Thalmann, Simone E. Hieber, Georg Schulz, Hans Deyhle, Anna Khimchenko, Vartan Kurtcuoglu, Ufuk Olgac, Anastasios Marmaras, Willy Kuo, Eric P. Meyer, Felix Beckmann, Julia Herzen, Stefanie Ehrbar, Bert Müller
Author Affiliations +
Abstract
Malfunction of oxygen regulation in kidney and liver may lead to the pathogenesis of chronic diseases. The underlying mechanisms are poorly understood. In kidney, it is hypothesized that renal gas shunting from arteries to veins eliminates excess oxygen. Such shunting is highly dependent on the structure of the renal vascular network. The vascular tree has so far not been quantified under maintenance of its connectivity as three-dimensional imaging of the vessel tree down to the smallest capillaries, which in mouse model are smaller than 5 μm in diameter, is a challenging task. An established protocol uses corrosion casts and applies synchrotron radiation-based micro-computed tomography (SRμCT), which provides the desired spatial resolution with the necessary contrast. However, SRμCT is expensive and beamtime access is limited. We show here that measurements with a phoenix nanotomrm (General Electric, Wunstorf, Germany) can provide comparable results to those obtained with SRμCT, except for regions with small vessel structures, where the signal-to-noise level was significantly reduced. For this purpose the nanotom®m measurement was compared with its corresponding measurement acquired at the beamline P05 at PETRA III at DESY, Hamburg, Germany.
© (2014) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Peter Thalmann, Simone E. Hieber, Georg Schulz, Hans Deyhle, Anna Khimchenko, Vartan Kurtcuoglu, Ufuk Olgac, Anastasios Marmaras, Willy Kuo, Eric P. Meyer, Felix Beckmann, Julia Herzen, Stefanie Ehrbar, and Bert Müller "Three-dimensional registration of synchrotron radiation-based micro-computed tomography images with advanced laboratory micro-computed tomography data from murine kidney casts", Proc. SPIE 9212, Developments in X-Ray Tomography IX, 92120Y (18 September 2014); https://doi.org/10.1117/12.2060809
Lens.org Logo