Paper
7 January 2015 Diagnostic system for cryogenically cooled 10 Hz Yb:YAG laser
Author Affiliations +
Proceedings Volume 9442, Optics and Measurement Conference 2014; 94420N (2015) https://doi.org/10.1117/12.2086616
Event: Optics and Measurement Conference 2014, 2014, Liberec, Czech Republic
Abstract
The ELI Beamlines facility will house repetition rate high-power lasers with pulse durations down to 15 fs and over petawatt peak powers. Our research group participates in the construction of a cryogenically cooled Yb:YAG multi-slab amplifier; part of the L2 beamline. The system shall provide square, super-Gaussian beam with nearly 2 ns pulses with rectangular temporal profile and energy of up to 10 J at 10 Hz. The laser will provide pump beams for broadband OPCPA stages. The diagnostic system of the pump laser is critical for the correct performance analysis, stabilization feedback and mostly for the machine interlock system as damages of the expensive optical components can develop very fast with the 10 Hz repetition rate. The diagnostic system provides key laser parameters and characteristics in temporal, spectral and spatial domain. The paper describes testing of the setup for measurements of the final 10 J output. Its design is based on a combination of optical wedges and diffractive sampler to facilitate multiple diagnostics on a relatively small footprint. The laser diagnostics package covers measurements in spatial domain such as near-field, far-field, or wavefront analysis, further optical spectrum, pulse energy and temporal shape. In order to detect possible damage dark-field analysis was implemented as well. The final setup was modeled in optical design software (Radiant Zemax) to understand its behavior and later tested together with real-time LabVIEW code developed by our group as being part of the machine interlock system. The first results of the tests as well as detailed description of the diagnostics package design are presented.
© (2015) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Lucia Koubíková, Jiří Thoma, Jack A. Naylon, Lukáš Indra, Martin Fibrich, Daniel Kramer, and Bedrich Rus "Diagnostic system for cryogenically cooled 10 Hz Yb:YAG laser", Proc. SPIE 9442, Optics and Measurement Conference 2014, 94420N (7 January 2015); https://doi.org/10.1117/12.2086616
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Diagnostics

Optical amplifiers

Laser systems engineering

Telescopes

Near field

Near field optics

Cameras

RELATED CONTENT

1030nm DBR tapered diode laser with up to 16 W...
Proceedings of SPIE (February 20 2017)
ARGOS: a laser star constellation for the LBT
Proceedings of SPIE (July 22 2010)
Overview of small optics for the National Ignition Facility
Proceedings of SPIE (November 11 1999)
Design and performance of a laser guide star system for...
Proceedings of SPIE (September 11 1998)

Back to Top