Paper
3 October 2016 Evaluation of a photon counting Medipix3RX CZT spectral x-ray detector
Author Affiliations +
Abstract
We assessed the performance of a cadmium zinc telluride (CZT)-based Medipix3RX x-ray detector as a candidate for micro-computed tomography (micro-CT) imaging. This technology was developed at CERN for the Large Hadron Collider. It features an array of 128 by 128, 110 micrometer square pixels, each with eight simultaneous threshold counters, five of which utilize real-time charge summing, significantly reducing the charge sharing between contiguous pixels. Pixel response curves were created by imaging a range of x-ray intensities by varying x-ray tube current and by varying the exposure time with fixed x-ray current. Photon energy-related assessments were made by flooding the detector with the tin foil filtered emission of an I-125 radioisotope brachytherapy seed and sweeping the energy threshold of each of the four charge-summed counters of each pixel in 1 keV steps. Long term stability assessments were made by repeating exposures over the course of one hour. The high properly-functioning pixel yield (99%), long term stability (linear regression of whole-chip response over one hour of acquisitions: y = -0.0038x + 2284; standard deviation: 3.7 counts) and energy resolution (2.5 keV FWHM (single pixel), 3.7 keV FWHM across the full image) make this device suitable for spectral micro-CT. The charge summing performance effectively reduced the measurement corruption caused by charge sharing which, when unaccounted for, shifts the photon energy assignment to lower energies, degrading both count and energy accuracy. Effective charge summing greatly improves the potential for calibrated, energy-specific material decomposition and K edge difference imaging approaches.
© (2016) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Steven M. Jorgensen, Andrew J. Vercnocke, David S. Rundle, Philip H. Butler, Cynthia H. McCollough, and Erik L. Ritman "Evaluation of a photon counting Medipix3RX CZT spectral x-ray detector", Proc. SPIE 9969, Radiation Detectors: Systems and Applications XVII, 99690J (3 October 2016); https://doi.org/10.1117/12.2236501
Lens.org Logo
CITATIONS
Cited by 5 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Sensors

X-rays

X-ray detectors

X-ray imaging

X-ray sources

Cameras

Image resolution

RELATED CONTENT

Soil matrix study using a hybrid a Se CMOS pixel...
Proceedings of SPIE (October 17 2022)
Development of a soft x ray ptychography beamline at SSRL...
Proceedings of SPIE (September 18 2015)
Multiple-view stereoscopic line-scan imaging
Proceedings of SPIE (May 23 2002)
Measurements of micro focus spot size (0.005 0.1mm) in x...
Proceedings of SPIE (December 07 2006)
High energy x ray source generation by short pulse high...
Proceedings of SPIE (January 07 2004)

Back to Top