14 June 2019 Terahertz confocal microscopy with an injection-seeded terahertz parametric generator
Weipeng Kong, Zeyu Li, Guangbin Li, Qiang Yan, Mingrui Zou, Xun Zhou, Yu Qin
Author Affiliations +
Abstract
We report on the implementation of a confocal microscopy system based on an injection-seeded terahertz parametric generator working at 1.76 THz. The system has a fairly reliable long-term stable operation with pulse energy fluctuations <5  %  . We experimentally demonstrate a subwavelength lateral resolution of 158  μm, corresponding to 0.93λ. We also demonstrate the capability of resolving overlapping objects at the different longitudinal surfaces by imaging a designed sample. This is the first detailed demonstration of confocal microscopy based on a THz parametric source, which is helpful for the practical application of THz imaging technology.

1.

Introduction

Terahertz (THz) confocal microscopy is very promising for THz nondestructive testing and industry quality inspection.15 As THz waves can penetrate nonpolar and nonmetallic materials, confocal technology can enhance resolution and achieve optical sectioning.6,7 Many efforts have been made in the field of THz confocal microscopy. Salhi et al.8 first introduced a transmission confocal microscope by utilizing an optically pumped THz gas laser working at 2.52 THz. Zinov’ev et al.9 reported on a configuration of confocal spatial filtering using a THz photoconductive antenna. Cumis et al.10 reported on the implementation of a confocal microscopy system based on a 2.9-THz quantum cascade laser operating at the temperature of 29 K. Li et al.11 presented a dual-axis reflection confocal microscope system working at 2.52 THz supported by an optically pumped THz gas laser.

The injection-seeded terahertz parametric generator (is-TPG) has been dramatically improved both in output power and sensitive detection technology since 2012.12 The development of is-TPG allows building THz confocal microscopy systems that are not only compact but also operating at room temperature. In addition, the tunability of is-TPG is one of the best merits compared with other monochromatic THz sources mentioned above.

In this work, we demonstrate a THz confocal microscopy based on an is-TPG working at a frequency of 1.76 THz. The system has considerable reliability for long-term stable operation. The lateral resolution of subwavelength is achieved. We also show the experiment for axial sections imaging.

2.

Experimental Setup

The schematic diagram of the experimental setup for the THz confocal microscopy is shown in Fig. 1. The employed is-TPG was working at 1.76 THz, corresponding to a wavelength of 170  μm. The output pulse energy was about 1.1  μJ with the repetition rate of 100 Hz. The THz beam is collimated by an f=50  mm Tsurupica cylinder lens (L1) and focused by an f=100  mm Tsurupica lens into the first pinhole (PH1). PH1 has a diameter of 1  mm. Parabolic mirrors (PM1 and PM2) are used to deliver and focus the THz beam to the sample; the other two parabolic mirrors (PM3 and PM4) are applied to collect and focus the THz beam into the detector (Golay Cell, Tydex, Inc.: GC-1D). PH2 (0.5-mm large in diameter) is the second confocal pinhole locating in front of the detector. The sample is mounted on an x–y–z scanner. The numerical aperture (NA) of PM1, PM2, PM3, and PM4 are 0.124, 0.447, 0.447, and 0.243, respectively. As the average power of is-TPG is relatively low, the choices of pinholes are mainly based on the sensitivity of the detector. For PM2 and PM3, we chose the mirrors with the largest NA in our lab, while keeping enough space for sample scanning.

Fig. 1

Scheme of the confocal THz microscope.

OE_58_6_060503_f001.png

We fixed a pinhole with 0.5-mm diameter in front of the detector and put the detector at the position where the beam pattern was to be measured. By scanning the detector in x and y axes, and recording the energy, the beam patterns were obtained. The original output beam pattern directly from is-TPG is shown in Fig. 2(a). The measurement was carried out at the position of L1 while the lenses were not located. The divergence of the beam along the y axis is much larger than that along the x axis. The beam pattern at the focal plane between PM2 and PM3 is shown in Fig. 2(b). A round beam shape in Fig. 2(b) benefits from the cylinder lens and PH1.

Fig. 2

(a) The original output beam pattern directly from is-TPG at the position of L1 and (b) the focus beam pattern around the focal plane between PM2 and PM3. Both beam patterns are normalized to their maxima.

OE_58_6_060503_f002.png

The stability of the system was measured for long-term operation with the is-TPG output energy of 1.1  μJ/pulse. THz waves were chopped to the frequency of 5 Hz, and then detected by the Golay Cell with a lock-in amplifier (lock-in frequency: 5 Hz). Figure 3 shows the fluctuation of THz-wave output energy within 12 h. Each dot indicates the sum of the energy of 10 pulses. Based on the root mean square error equation ΔE¯={[i=1n(EiE¯)2]/n}1/2, where Ei is the measured energy in the i’th measurement, E¯=i=1nEi/n, ΔE¯ was calculated to be 1.5%, and then the single-pulse energy fluctuation was calculated to be 10ΔE¯=4.88%.

Fig. 3

Long-term (12 h) stability of the is-TPG output.

OE_58_6_060503_f003.png

We employed the knife-edge method to measure the scanning spot size around the focal plane.13 We recorded the intensity profiles of x and y axes by sequentially blocking the beam with a knife blade. Then we fitted the intensity profiles to the Gaussian function to get the beam widths. The result is shown in Fig. 4, which is the full-width at half-maximum (FWHM) as a function of z. The minimum values of FWHM on x axis and y axis are 238 and 255  μm, respectively. Microscope resolution is directly related to the FWHM of point spread function. Measurements of resolution utilizing the FWHM values are somewhat smaller than those calculated employing the Rayleigh criterion. The estimated lateral resolution is 152  μm and the estimated axial resolution is 596  μm using: rlateral=0.4λ/NA and raxial=0.7λ/NA2,8,14 where NA is set to 0.447.

Fig. 4

Beam FWHM along the z axis around the focal plane, obtained with the knife-edge method.

OE_58_6_060503_f004.png

3.

Experimental Results

The lateral resolution of the microscope based on the is-TPG was tested using a 1951 USAF resolution test plate (Edmund Optics Inc.). By scanning the test plate in two dimensions at the focal plane, the THz image is obtained as shown in Fig. 5(a). The area of the image has a dimension of 20×15  mm2 (200×150  pixels), the resolution of x and y axes is better than 3.17  lp/mm [line pairs indicated by the rectangle box in Fig. 5(a)], which corresponds to 158  μm. Figures 5(b) and 5(c) show the 1-D intensity distributions along the 110’th column and 145’th row, respectively [indicated by the arrows in Fig. 5(a)]. Both curves in Figs. 5(b) and 5(c) are normalized to [0, 1]. According to the Rayleigh criterion, two lines can be resolved while the contrast C=(ImaxImin)/Imax is larger than 0.265,15 where I is the intensity. Calculated by the results shown in Figs. 5(b) and 5(c), the contrasts in x and y direction are 0.523 and 0.343, respectively, which are larger than the critical value of 0.265.

Fig. 5

(a) Measured THz image of a 1951 USAF resolution testing plate and the normalized 1-D intensity distributions along (b) the 110th column and (c) 145th row. The solid box in (a) shows the position of line pairs 5, whereas the arrows in (a) show the locations of the 110th column and 145th row.

OE_58_6_060503_f005.png

Furthermore, we designed an experiment to show the capability of axial sectioning. Two hairs are stuck to the front and back surfaces of a 2-mm-thick TPX plate using Scotch tapes as the sample. The sample is moved along the z axis between PM2 and PM3. Figure 6(a) shows the schematics of the experimental arrangement. Figures 6(b) and 6(c) were captured when the front and back surfaces of the TPX plate were just at the focal plane. The scanning dimension was 12×12  mm2 (120×120  pixels), and the scanning time was 4 h for each picture. The position of the hair and tapes on both sides can be identified by the intensity level and imaging clarity. We can make judgments that the vertical hair and lateral tapes are located on the front surface, while the horizontal hair and longitudinal tapes are located on the back surface. The unclearness of the elements in Fig. 6(c) is due to the contrast reduction caused by the loss of THz energy due to reflection and scattering.

Fig. 6

(a) Schematic diagrams of the experimental setup and measured THz image of (b) front and (c) back surfaces of the sample.

OE_58_6_060503_f006.png

4.

Conclusions and Outlook

In this letter, we present the THz confocal microscopy system based on an is-TPG. The is-TPG provides stable THz output during the whole scanning process with the single-pulse energy fluctuation less than 5%. The subwavelength lateral resolution of 158  μm is achieved at 1.76 THz. In addition, the system is also capable to resolve objects located at the front and back surfaces of the sample in the designed experiment. Resolution and contrast can be further improved by increasing the NA and reducing the size of the pinholes in the current system.

It is worth mentioning that a considerable amount of the energy was lost due to the numerous optical components on the beam path. The efficiency of the microscope is <0.1%. With the low-average power of is-TPG, more sensitive detection methods like up-conversion detection is necessary for future work that allows the system to achieve a dynamic range up to 70 dB.12 We also notice that the repetition rate of the is-TPG system has reached up to 100 kHz, which means the acquisition time can be shortened to 1/150 by modification of the pump method.16 Furthermore, pulse energy fluctuations can be calibrated using the pump or idler light in the parametric process to achieve better stability.

It is foreseeable that in the future, with the improvements of the THz parametric source and sensitive detection method, the image quality of the THz confocal microscopy based on is-TPG can be greatly improved, and such a system can be very practical in the 1- to 2.6-THz band.

Acknowledgments

This work was supported by the National Natural Science Foundation of China (No. 11804320).

References

1. 

J. B. Jackson et al., “Terahertz imaging for non-destructive evaluation of mural paintings,” Opt. Commun., 281 (4), 527 –532 (2008). https://doi.org/10.1016/j.optcom.2007.10.049 OPCOB8 0030-4018 Google Scholar

2. 

S. Wietzker et al., “Terahertz imaging: a new non-destructive technique for the quality control of plastic weld joints,” J. Eur. Opt. Soc. Rapid Publ., 2 07013 (2007). https://doi.org/10.2971/jeos.2007.07013 Google Scholar

3. 

F. Rutz et al., “Terahertz quality control of polymeric products,” Int. J. Infrared Millimeter Waves, 27 (4), 547 –556 (2006). https://doi.org/10.1007/s10762-006-9106-7 Google Scholar

4. 

N. Karpowicz et al., “Non-destructive sub-THz CW imaging,” Proc. SPIE, 5727 132 –142 (2005). https://doi.org/10.1117/12.590539 PSISDG 0277-786X Google Scholar

5. 

W. E. Baughman et al., “Comparative reconstructions of THz spectroscopic imaging for non-destructive testing and biomedical imaging,” Proc. SPIE, 8363 21 (2012). https://doi.org/10.1117/12.919627 PSISDG 0277-786X Google Scholar

6. 

M. Tonouchi, “Cutting-edge terahertz technology,” Nat. Photonics, 1 (2), 97 –105 (2007). https://doi.org/10.1038/nphoton.2007.3 NPAHBY 1749-4885 Google Scholar

7. 

M. Minsky, “Memoir on inventing the confocal scanning microscope,” Scanning, 10 (4), 128 –138 (1988). https://doi.org/10.1002/sca.4950100403 SCNNDF 0161-0457 Google Scholar

8. 

M. Salhi, P. Ioachim and K. Martin, “Confocal THz laser microscope,” Int. J. Infrared Millimeter Waves, 31 (3), 358 –366 (2009). https://doi.org/10.1007/s10762-009-9590-7 Google Scholar

9. 

N. N. Zinov’ev and A. V. Andrianov, “Confocal terahertz imaging,” Appl. Phys. Lett., 95 (1), 011114 (2009). https://doi.org/10.1063/1.3173200 APPLAB 0003-6951 Google Scholar

10. 

U. S. D. Cumis et al., “Terahertz confocal microscopy with a quantum cascade laser source,” Opt. Express, 20 (20), 21924 –21931 (2012). https://doi.org/10.1364/OE.20.021924 OPEXFF 1094-4087 Google Scholar

11. 

Q. Li et al., “2.52 terahertz dual-axis reflection confocal scanning microscope,” J. Opt. Soc. Am. A, 33 (4), 637 –641 (2016). https://doi.org/10.1364/JOSAA.33.000637 JOAOD6 0740-3232 Google Scholar

12. 

H. Minamide et al., “Kilowatt-peak terahertz-wave generation and sub-femtojoule terahertz-wave pulse detection based on nonlinear optical wavelength-conversion at room temperature,” J. Infrared Millimeter Terahertz Waves, 35 (1), 25 –37 (2014). https://doi.org/10.1007/s10762-013-0041-0 Google Scholar

13. 

Y. Qin et al., “Characterization of non-Gaussian mid-infrared free-electron laser beams by the knife-edge method,” Infrared Phys. Technol., 66 146 –151 (2014). https://doi.org/10.1016/j.infrared.2014.05.021 IPTEEY 1350-4495 Google Scholar

14. 

N. S. Claxton, T. Fellers and M. Davidson, “Laser scanning confocal microscopy,” (2006). http://www.aptechnologies.co.uk/images/Data/Vertilon/PP6207.pdf Google Scholar

15. 

G. S. Kino and R. C. Timothy, Confocal Scanning Optical Microscopy and Related Imaging Systems, Academic Press, San Diego (1996). Google Scholar

16. 

Y. Moriguchi et al., “High-average and high-peak output-power terahertz-wave generation by optical parametric down-conversion in MgO:LiNbO3,” Appl. Phys. Lett., 113 (12), 121103 (2018). https://doi.org/10.1063/1.5046126 APPLAB 0003-6951 Google Scholar
CC BY: © The Authors. Published by SPIE under a Creative Commons Attribution 4.0 Unported License. Distribution or reproduction of this work in whole or in part requires full attribution of the original publication, including its DOI.
Weipeng Kong, Zeyu Li, Guangbin Li, Qiang Yan, Mingrui Zou, Xun Zhou, and Yu Qin "Terahertz confocal microscopy with an injection-seeded terahertz parametric generator," Optical Engineering 58(6), 060503 (14 June 2019). https://doi.org/10.1117/1.OE.58.6.060503
Received: 3 April 2019; Accepted: 29 May 2019; Published: 14 June 2019
Lens.org Logo
CITATIONS
Cited by 3 scholarly publications.
Advertisement
Advertisement
KEYWORDS
Terahertz radiation

Confocal microscopy

Lithium

Microscopes

Sensors

Mirrors

Gas lasers

Back to Top