Quantitative phase imaging (QPI) techniques require multiple measurements to obtain the refractive index (RI) distribution of a sample. Here, we present a single-shot RI imaging method using spectral multiplexing and optical transfer function reshaping. In the present method, we simultaneously measure three intensity images of a sample with three optimized illumination patterns. Deconvolution of the measured intensity images is then performed to obtain the RI distribution of the sample. As a proof-of-concept, we measured both microspheres and biological cells.
PERSONAL Sign in with your SPIE account to access your personal subscriptions or to use specific features such as save to my library, sign up for alerts, save searches, etc.
The alert did not successfully save. Please try again later.
Chungha Lee, Hugonnet Herve, Juyeon Park, Mahn Jae Lee, Weisun Park, YongKeun Park, "Single-shot refractive index imaging using spectral multiplexing and optical transfer function reshaping (Conference Presentation)," Proc. SPIE PC12389, Quantitative Phase Imaging IX, PC123890K (16 March 2023); https://doi.org/10.1117/12.2653811