Paper
27 December 2002 Photomask Dimensional Metrology in the SEM: Has Anything Really Changed?
Author Affiliations +
Abstract
Photomask dimensional metrology in the scanning electron microscope (SEM) has not evolved as rapidly as the metrology of resists and integrated circuit features on wafers. This has been due partly to the 4x (or 5x) reduction in the optical steppers and scanners used in the lithography process, and partly for the lesser need to account for the real three-dimensionality of the mask structures. So, where photomasks are concerned, many of the issues challenging wafer dimensional metrology at 1x are reduced by a factor of 4 or 5 and thus could be temporarily swept aside. This is rapidly changing with the introduction of advanced masks with optical proximity correction and phase shifting features used in 100 nm and smaller circuit generations. Fortunately, photomask metrology generally benefits from the advances made for wafer metrology, but there are still unique issues to be solved in this form of dimensional metrology. It is likely that no single metrology method or tool will ever provide all necessary answers. As with other types of metrology, resolution, sensitivity and linearity in the three-dimensional measurements of the shape of the lines and phase shifting features in general (width, height and wall angles) and the departures from the desired shape (surface and edge roughness, etc.) are the key parameters. Different methods and tools differ in their ability to collect averaged and localized signals with an acceptable speed, but in any case, application of this thorough knowledge of the physics of the given metrology is essential to extract the needed information. This paper will discuss the topics of precision, accuracy and traceability in the SEM metrology of photomasks. Current and possible new techniques utilized in the measurements of photomasks including charge suppression and highly accurate modeling for electron beam metrology will also be explored to answer the question “Has anything really changed?”
© (2002) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Michael T. Postek Jr., Andras E. Vladar, and Marylyn Hoy Bennett "Photomask Dimensional Metrology in the SEM: Has Anything Really Changed?", Proc. SPIE 4889, 22nd Annual BACUS Symposium on Photomask Technology, (27 December 2002); https://doi.org/10.1117/12.467760
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Metrology

Photomasks

Scanning electron microscopy

Standards development

Semiconducting wafers

Electron beams

Dimensional metrology