Paper
21 September 2012 Phase induced amplitude apodization (PIAA) coronagraphy: recent results and future prospects
Author Affiliations +
Abstract
Thanks to the use of aspheric optics for lossless apodization, the Phase Induced Amplitude Apodization (PIAA) coronagraph offers full throughput, high contrast and small inner working angle. It is therefore ideally suited for space-based direct imaging of potentially habitable exoplanets. The concept has evolved since its original formulation to mitigate manufacturing challenges and improve performance. Our group is currently aiming at demonstrating PIAA coronagraphy in the laboratory to 1e-9 raw contrast at 2 λ/D separation. Recent results from the High Contrast Imaging Testbed (HCIT) at JPL demonstrate contrasts about one order of magnitude from this goal at 2 λ/D. In parallel with our high contrast demonstration at 2 λ/D, we are developing and testing new designs to reduce inner working angle and improve performance in polychromatic light. The newly developed PIAA complex mask coronagraph (PIAACMC) concept provides total starlight extinction and offers full throughput with a sub- λ/D inner working angles. We also describe a recent laboratory demonstration of fine pointing control with PIAA.
© (2012) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Olivier Guyon, Brian Kern, Ruslan Belikov, Stuart Shaklan, Andreas Kuhnert, Amir Give'on, and Frantz Martinache "Phase induced amplitude apodization (PIAA) coronagraphy: recent results and future prospects", Proc. SPIE 8442, Space Telescopes and Instrumentation 2012: Optical, Infrared, and Millimeter Wave, 84424V (21 September 2012); https://doi.org/10.1117/12.927187
Lens.org Logo
CITATIONS
Cited by 2 scholarly publications and 1 patent.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Coronagraphy

Apodization

Telescopes

Space telescopes

Aspheric optics

Calibration

Exoplanets

RELATED CONTENT

Imaging Earth like planets around late type stars with low...
Proceedings of SPIE (September 26 2013)
Occulter design for THEIA
Proceedings of SPIE (August 19 2009)
Diffractive pupil telescope for high precision space astrometry
Proceedings of SPIE (September 15 2011)
Advanced speckle sensing for internal coronagraphs
Proceedings of SPIE (September 15 2011)
TOPS a small space telescope using phase induced amplitude...
Proceedings of SPIE (September 19 2007)
Improvement of coronagraphy using optimal apodizations
Proceedings of SPIE (March 03 2003)

Back to Top