1.IntroductionNoninvasive tissue fluorescence analysis by conventional spectroscopic techniques presents significant challenges because of the absorption and scattering of light in tissues.1 Visualization of fluorescent probes in tissues, such as the distribution of a fluorescent drug, has been achieved by whole-body imaging.2 However, this approach requires large amounts of a fluorescent material, and it is difficult to obtain quantitative information at low fluorophore concentrations. Our group has demonstrated a minimally invasive technique, using a two-photon optical fiber fluorescence (TPOFF)–based detection system for the quantification of tissue fluorescence both in vitro and in live animals.3, 4 As compared to single-photon excitation,5 two-photon excitation has the advantage of having greater penetration into tissue samples.6, 7 Moreover, analytes with multiple emission wavelengths can be simultaneously quantified using a single-excitation laser beam due to the broad two-photon excitation cross-section spectra. As the two-photon excitation and emission wavelengths are widely separated and can be easily filtered, the sensitivity of detection is enhanced, especially for multiwavelength analytes. In our previous studies, we have used a single-mode fiber (SMF) to deliver femtosecond laser pulses into cell and tissue samples and to collect the emitted fluorescence back through the same fiber. This allowed the detection and quantification of targeted fluorescent antibodies and nanoparticles.3, 4, 8 One of the limitations of a SMF is that its small numerical aperture (NA, ) results in inefficient signal collection. To quantify low levels of localized fluorescence such as those that occur with tissue-specific targeting of a nanoparticle, a more sensitive in situ fluorescence quantification technique is required. Although the application of a multimode fiber (MMF) would enable efficient fluorescence collection through its large NA, the sensitivity for two-photon fluorescence is compromised because of its inefficient excitation and lower resolution. To solve these “trade-off” problems between the SMF and the MMF, we have recently reported the development of a double-clad photonic crystal fiber (DCPCF) that allows SMF-like high resolution excitation through its center core while collecting the emitted light efficiently through both the inner core and an outer core that has a large NA .9 We demonstrated the use of a DCPCF as a scanning microscope for visualizing fluorescent images of individual cells, using a gradient index lens attached at the end of the fiber. However, the use of a DCPCF for in situ fluorescence quantification is limited because of the entry of fluids into its outer core airspace by capillary action. In this paper, we demonstrate the application of a solid double-clad optical fiber (DCF) that, because it does not need air holes for the optical confinement in the outer core, avoids the entry of biological fluids into the fiber. Although the DCF has a slightly lower NA and collection efficiency versus the DCPCF, it provides a significant improvement over conventional single-clad SMFs. Our studies show for the first time that the improved sensitivity of a DCF as compared to that of a single-clad fiber allows sensitive quantification of targeted nanoparticles in tumor cells. 2.Materials and Methods2.1.MaterialsThe generation 5 (G5) poly(amidoamine) (PAMAM) dendrimer was synthesized and characterized at the Michigan Nanotechnology Institute for Medicine and Biological Sciences, University of Michigan. Methanol ( , high performance liquid chromatography [HPLC] grade), acetic anhydride (99%), triethylamine (99.5%), dimethyl sulfoxide (DMSO, 99.9%), dimethylformamide (DMF, 99.8%), l-[3-(dimethylamino)propyl]-3-ethylcarbodiimide (EDC, 98%), citric acid (99.5%), sodium azide (99.99%), , , and volumetric solutions ( and ) for potentiometric titration were purchased from Aldrich Co. (Milwaukee, Wisconsin) and used as received. The Spectra/Por dialysis membrane (MWCO 3500) and Millipor Centricon ultrafiltration membrane (YM-10) were from Fisher Scientific (Hanover Park, Illinois). The 6-carboxytetramethyl rhodamine, succinimidyl ester (6-TAMRA-SE, 6T-SE, properties: molecular=528, soluble in DMF and DMSO, absorption=546, emission=576 measured in , ) was purchased from Invitrogen (Carlsbad, California). The KB cells were obtained from ATCC (Rockville, Maryland). Female, severe combined immunodeficiency (SCID) mice were purchased from Charles River Laboratories (Wilmington, Massachusetts). The SMF and DCF were from Newport (F-SBA; Irvine, California) and Thorlab (P-10/123DC, Newton, NewJersey). Roswell Park Memorial Institute (RPMI) cell culture medium, trypsin–ethylenediamine tetraacetic acid, penicillin/streptomycin, and Dulbecco’s phosphate buffered saline (PBS, pH 7.4) were from Gibco/BRL (Gaithersburg, Maryland). Folate-deficient diet was from TestDiet (Richmond, Indiana). Folic acid (FA, 98%) and all other reagents were from Sigma (St. Louis, Missouri). 2.2.Methods2.2.1.Synthesis of G5-6T-FAWe have previously established the G5-PAMAM (G5) dendrimer nanoparticle as a suitable platform for conjugating multiple molecules for specific targeting of drugs and imaging agents into cells.10 The G5 dendrimer has several attractive properties as a molecular delivery platform, including uniformity, biocompatibility, defined branched chain structure, and the capability for chemically coupling multiple molecular entities to its surface amino groups. The three-dimensional architecture of the PAMAM dendrimers resembles globular proteins, and the G5 has the size of hemoglobin . PAMAM dendrimers are commercially available and are synthesized from an ethylene diamine (EDA) initiator core, with exhaustive Michael addition of methyl acrylate followed by condensation (amidation) reactions of the resulting ester with large excesses of EDA.10 PAMAM dendrimers have recently been shown to be highly suitable for drug delivery, detection of biochemical functions such as apoptosis, and for tumor imaging.10 For the FA receptor-specific targeting in vitro and in vivo, we synthesized the targeted and nontargeted conjugates G5-6TAMRA-folic acid (G5-6T-FA; compound 7, Fig. 1 ) and G5-6TAMRA (G5-6T; compound 4, Fig. 1), respectively, using procedures similar to those we have described previously.11 After the synthesis of each intermediary conjugate shown (Fig. 1), the product obtained was purified by intensive dialysis or by repeated ultrafiltration, using a 10-kDa membrane filter and using PBS followed by water. The purified compound was lyophilized before undergoing the subsequent reaction step. G5 carrier. The G5 dendrimer platform used in this study had a number average molecular weight of , as determined by gel permeation chromatography (GPC) equipped with multi angle laser light scattering and refractive index detectors. The average number of primary amino groups was 110, as determined by potentiometric titration. G5 with 70 amino groups acetylated [G5-Ac(70)]. Initially the primary amino groups on the G5 were partially acetylated. Acetylation of the primary amino groups was used to neutralize the positively charged primary amines on the dendrimer surface from further reaction or intermolecular interaction within biological systems. The quantity of G5 in of absolute was reacted with of acetic anhydride in the presence of ( , 25% molar excess) of triethylamine at room temperature and stirred overnight. The yield of the purified product was (89.64%), with an average of 70 acetyl groups as determined by proton nuclear magnetic resonance spectroscopy.12 Leaving 40 surface amines allows for the efficient attachment of multiple functionalities, such as receptor ligands, fluorescent dyes, and drugs.11 G5 with 70 acetyl groups and 4 covalently conjugated 6TAMRA [G5-Ac(70)-6T(4)]. To of G5-Ac(70) in of deionized (DI) water and of solution was added dropwise of 5-mg 6-TAMRA in DMSO solution at a reduced temperature. This was then stirred for . The yield of the purified product was (68%). Fully acetylated G5-6TAMRA [G5-Ac(fully)-6T(4)][“G5-6T,” control conjugate for biological testing]. As a standard procedure after conjugation of multiple functionalities, any free amine groups remaining are neutralized by acetylation to obtain a fully neutralized final product. A mixture of of G5-Ac(70)-6T(4) dendrimer conjugate, of acetic anhydride, and of triethylamine in of absolute was allowed to react at room temperature by stirring overnight. The purified product obtained (G5-6T) had a molecular weight of , as determined by GPC. G5 containing five covalently conjugated folic acid molecules [G5-Ac(70)-FA(5)]. Conjugation of FA to the partially acetylated dendrimer was carried out via condensation between the -carboxyl group of FA and the primary amino groups of the dendrimer. Because of the higher reactivity of the -carboxyl group of FA as compared to its -carboxyl, under the conditions used, conjugation takes place primarily through the -carboxyl. Leaving the -carboxyl of FA free is a prerequisite for its full affinity toward the FA receptor. The FA was initially activated by reacting of FA with a 14-fold excess of EDC ( , ) in a solvent mixture of of DMF and of DMSO at room temperature. After , the FA-active ester solution obtained was added dropwise to an aqueous solution of the partially acetylated product G5-Ac(70) ( , ) in of water. The reaction was allowed to proceed at room temperature with intensive stirring for three days. The yield of the purified product obtained was (99.8%), with five FA per dendrimer as determined by analysis.11 In the of the purified G5-6T-FA, the absence of any sharp peaks and the observed broadening of the aromatic proton peaks were indicative of the lack of presence of any free FA and the presence of covalently conjugated FA. Additional characterization by gel permeation column chromatography (equipped with a UV detector) and HPLC analysis also failed to show any presence of free FA. G5-Ac(70)-FA(5)-6T(4). To of G5-Ac(70)-FA(5) in DI water and of solution was added dropwise of 6-TAMRA in a DMSO solution at reduced temperature, and it was stirred for . The yield of the purified product was (90.1%). G5-Ac(fully)-FA(5)-6T(4) [“G5-6T-FA,” targeted conjugate for biological testing]. A combination of of G5-Ac(70)-FA(5)-6T(4) dendrimer conjugate, of acetic anhydride and of triethylamine in of absolute was allowed to react at room temperature overnight. GPC analysis of the product obtained (G5-6T-FA) gave a molecular weight of . On the basis of the integration values of the methyl protons in the acetamide groups and the aromatic protons by analysis, the numbers of attached FA and 6TAMRA molecules were calculated to be 5 and 4, respectively. 2.2.2.The TPOFF system—instrumentationThe TPOFF fluorescence detection system used was similar to that previously described.4 The SMF used in this study had a mode field diameter of with a NA of 0.16. The DCF had a diameter inner core with a NA of 0.07 and a cladding with a NA of 0.46 (Fig. 2 ). Femtosecond laser pulses generated from a Ti:sapphire oscillator (Mira 900, Coherent, Inc., Santa Clara, California) with a pulse duration of and center wavelength of were used as the excitation source. Fibers were directly inserted into dye solutions, cell pellets, or into tumor samples through a 30-gauge needle. The fluorescence emission was collected through the same fiber and then separated from the excitation beam by a dichroic mirror. The fluorescence was then sent through a short-pass filter and counted using a photon-counting photomultiplier tube. Cell culture and in vitro studiesThe KB cell line, which expresses high levels of FA receptor on its membrane, was used for the receptor-specific targeting of the G5-6T-FA conjugate. The KB cells were cultured as described previously.13 Cells were maintained in folate-free RPMI medium containing 10% serum to provide extracellular FA similar to that found in human serum. For in vitro studies, cells plated in 75-cc flasks were trypsinized, rinsed, and resuspended in phosphate buffered saline containing 0.1% bovine serum albumin (PBSB). The cells in suspension were treated with different concentrations of the conjugates for at , rinsed, and centrifuged to collect the cell pellets. The optical fiber was then inserted into different regions of the cell pellet and TPOFF counts were collected as described previously.14 Animal model and in vivo studiesFor in vivo studies, KB cell tumors were developed in seven-week-old SCID mice as described before.15 The mice were housed in a specific pathogen-free animal facility at the University of Michigan Medical Center in accordance with the regulations of the University’s Committee on the Use and Care of Animals as well as with federal guidelines, including the principles of laboratory animal care. The animals were fed ad libitum with Laboratory Autoclavable Rodent Diet 5010 (PMI Nutrition-International, St. Louis, Missouri). Two weeks before tumor cell injection, the food was changed to a folate-deficient diet. The KB cell tumors were developed by subcutaneous inoculation of 1 000 000 cells each in the left and right flank areas. The cells were trypsinized, rinsed, and injected as a 0.1-ml suspension using sterile PBS. The tumors were allowed to reach 0.7 to in diameter before analysis. We administered of the conjugates in of PBS, or PBS alone as a control, through the tail vein. At the end of the study, 15 hours later, the mice were anesthetized with isoflurane and the tumors were excised and frozen. The optical fibers were inserted into the tumor through a 30-guage needle, with the tip of the fiber placed at the proximal end of the needle hole. The needle with the fiber was sonicated in a bath sonicator between tumor sample measurements. The fluorescence of multiple internal regions of the tumors was quantified using the two-fiber probes under identical conditions. The statistical significance of differences among the groups was analyzed by the Student-Newman-Keuls test, with significance calculated at . 3.Results and DiscussionThe fluorescence emissions of the standard solutions of G5-6T-FA and G5-6T were initially quantified using DCF and SMF probes (Fig. 3 ). The DCF fiber showed lower background fluorescence when measured in PBS buffer and a five-fold higher conjugate fluorescence as compared to the SMF. The background fluorescence obtained in PBS was and , respectively, when the SMF and DCF probes were used. This detection background was mainly from the autofluorescence of the fiber core. The fact that the SMF has a higher background was attributed to the impurity of the material used for the SMF core. The low detection background of the DCF probe ensures the accurate measurements of samples with an extremely low concentration of fluorophores. Other independent measurements using the two fibers similar to what is presented in Fig. 3 have shown that the standard TPOFF counts were linear at least up to concentrations of the conjugates. This is consistent with the linearity in TPOFF counts up to concentrations of the “G5-fluorescein” conjugates we have previously demonstrated using the SMF.14 The background-subtracted counts [mean ] obtained for 5, 10, 30, 100, and of G5-6T-FA conjugate were, respectively, , , , , and using the DCF, and , , , , and for the SMF [Fig. 3b]. This shows that the lower detection limit for the conjugate is for the DCF and for the SMF. The increased sensitivity of the DCF versus the SMF is due to the unique fiber structure, which allows the laser beam to propagate in single mode through the inner core for a high excitation rate while having an efficient collection of fluorescence through its outer core (first clad), and is also due to the lower background fluorescence of the former. The DCF fiber was then utilized to quantify the in vitro targeting of the dendrimer conjugates in FA receptor-expressing KB cells. In untreated control cell pellets, the mean background fluorescence taken by the SMF and the DCF were and counts per second, respectively. This observation is in contrast to the increased background fluorescence of the SMF in PBSB. The increased DCF counts observed in the control cell pellet could be because of the autofluorescence of endogenous fluorophores. Several cellular components such as collagen, tryptophan, and porphyrins are known to be fluorescent, and low levels of these agents are apparently being detected by the more sensitive DCF fiber. As shown in Fig. 4a , the fluorescence of the cell pellet was significantly higher for the DCF fiber at all concentrations of the G5-6T-FA conjugate tested, consistent with results from the standard solutions. The increased sensitivity of the DCF fiber is further evident from the marked difference in the slopes of the two curves [Fig. 4a] at lower doses of the conjugate. Low levels of nonspecific binding of the control conjugate G5-6T were detected only by the DCF fiber [Fig. 4b]. The binding curves observed by the DCF fiber are indicative of the FA receptor-specific interaction we have previously reported.13 The receptor-specific binding of the G5-6T-FA was further confirmed by the reversal of the binding of of G5-6T-FA by preincubating cells with a 50-fold excess of free FA. The DCF-TPOFF counts in cells incubated with of G5-6T-FA in the absence and presence of of free FA were and , respectively. The standard error for the measurement of different regions of the cell pellets varied from 2% to 20% for the different concentrations of the conjugate tested. As the TPOFF measurement quantifies the fluorescence of only a few microns surrounding the fiber, this variablity could result from the differences in the fluorescence intensities for the 4 to 5 cell regions tested in cell pellets at each concentration. A broad population distribution for binding of the conjugate has been observed by flow cytometry by measurement of the individual fluorescence of cells.3 The DCF probe was then used to confirm our previous findings3, 4 that the G5-6T-FA conjugate could target FA receptor-expressing tumors in vivo in mice. As shown in Fig. 5 , there were approximately three-fold greater background-subtracted counts for the targeted conjugate as detected by the DCF probe in comparison to the counts obtained by the SMF probe. There was a three- to four-fold increase in the uptake of the targeted conjugate (G5-6T-FA) in comparison to the control conjugate G5-6T, which again is consistent with our previous findings.3, 4 Using the slope of the standard curve generated for the G5-6T-FA (Fig. 3), the concentration of the targeted conjugate in the tumor was and measured by the DCF and SMF, respectively. In keeping with these results, our previous studies using the SMF have shown the accumulation of 1 to of G5-6T-FA in KB tumors.3, 4 4.ConclusionThe results in this study demonstrate that the DCF-TPOFF has at least a three-fold improved tissue detection limit compared to the similar-in-diameter SMF used under similar conditions. Although the tissue background fluorescence due to endogenous fluorescent cell components is increased because of the improved sensitivity of the DCF probe, selection of appropriate fluorophores with emission wavelengths separated from endogenous emissions (e.g., red-shifted fluorophores such as Deep Red) for analysis is expected to further increase the resolution and sensitivity of the DCF. On the other hand, an understanding of the ratio of the sensitive endogenous fluorescence to that of the exogenously administered component may facilitate the more accurate determination of time-dependent changes with variables such as the power or coupling of the laser over time. The core of the DCF fiber used in this study is twice as large as that of SMF, causing lower peak intensity at the excitation end of the DCF fiber, and the usage of fibers with a comparable core size would further enhance the sensitivity of the DCF probe. The improved sensitivity of the DCF versus the SMF and the application of a small 30-guage needle make this a superior optical fiber probe technique in quantifying fluorescent signals in deep tissues. Nanomolar quantities of multiple fluorophores with different emission wavelengths or lifetimes could be discerned and quantified using this technique. We envision that the TPOFF probe will serve as a minimally invasive diagnostic tool for screening tumor markers, such as the epidermal growth factor–receptor 2 (HER2) in women with breast cancer, when used in conjunction with a fluorescent marker such as the fluorescently tagged antibody Herceptin. Currently, efforts are also underway to modify the DCPCF to prevent it from interacting with fluids while retaining its superior optical characteristics. AcknowledgmentsThis project has been funded in whole or in part with federal funds from the National Cancer Institute, National Institutes of Health, under Grants Nos. 1 R33 CA112141 and 1 R21 RR021893. References
“Tissue diagnostics using lasers,”
Lasers in Medicine, 135
–169 CRC Press, Boca Raton, FL (2002). Google Scholar
R. Weissleder and
V. Ntziachristos,
“Shedding light onto live molecular targets,”
Nat. Med., 9
(1), 123
–128
(2003). 1078-8956 Google Scholar
T. P. Thomas,
J. Y. Ye,
C.-S. Yang,
M. T. Myaing,
I. J. Majoros,
A. Kotlyar,
Z. Cao,
T. B. Norris, J. R. Baker Jr.,
“Tissue distribution and real-time fluorescence measurement of a tumor-targeted nanodevice by a two photon optical fiber fluorescence probe,”
Proc. SPIE, 6095 60950Q
(2006). 0277-786X Google Scholar
T. P. Thomas,
M. T. Myaing,
J. Y. Ye,
K. Candido,
A. Kotlyar,
J. Beals,
P. Cao,
B. Keszler,
A. K. Patri,
T. B. Norris, J. R. Baker Jr.,
“Detection and analysis of tumor fluorescence using a two-photon optical fiber probe,”
Biophys. J., 86
(6), 3959
–3965
(2004). https://doi.org/10.1529/biophysj.103.034462 0006-3495 Google Scholar
B. M. Cullum,
G. D. Griffin,
G. H. Miller, and
T. Vo-Dinh,
“Intracellular measurements in mammary carcinoma cells using fiber-optic nanosensors,”
Anal. Biochem., 277
(1), 25
–32
(2000). 0003-2697 Google Scholar
J. C. Jung and
M. J. Schnitzer,
“Multiphoton endoscopy,”
Opt. Lett., 28
(11), 902
–904
(2003). https://doi.org/10.1364/OL.28.000902 0146-9592 Google Scholar
A. Periasamy, Methods in Cellular Imaging,
(2001) Google Scholar
T. P. Thomas,
A. K. Patri,
A. Myc,
M. T. Myaing,
J. Y. Ye,
T. B. Norris, J. R. Baker Jr.,
“In vitro targeting of synthesized antibody-conjugated dendrimer nanoparticles,”
Biomacromolecules, 5
(6), 2269
–2274
(2004). 1525-7797 Google Scholar
J. Y. Ye,
M. T. Myaing,
T. P. Thomas,
I. Majoros, A. Kotlyar J. R. Baker Jr., W. Wadsworth,
J. G. Bouwmans,
J. C. Knight,
P. St. J. Russell, and
T. B. Norris,
“Development of a dual-clad photonic-crystal-fiber based scanning microscope,”
Proc. SPIE, 5700 23
–27
(2005). https://doi.org/10.1117/12.589344 0277-786X Google Scholar
T. P. Thomas,
R. Shukla,
I. J. Majoros,
A. Myc, J. R. Baker Jr.,
“Poly(amidoamine) dendrimer-based multifunctional nanoparticles,”
Nanobiotechnology: Concepts, Methods and Perspectives, Wiley-VCH, Weinheim, Germany (2004). Google Scholar
I. J. Majoros,
T. P. Thomas,
C. B. Mehta, J. R. Baker Jr.,
“Poly(amidoamine) dendrimer-based multifunctional engineered nanodevice for cancer therapy,”
J. Med. Chem., 48
(19), 5892
–5899
(2005). 0022-2623 Google Scholar
I. J. Majoros,
B. Keszler,
S. Woehler,
T. Bull, J. R. Baker Jr.,
“Acetylation of poly (amidoamine) dendrimers,”
Macromolecules, 36 5526
–5529
(2003). 0024-9297 Google Scholar
T. P. Thomas,
I. J. Majoros,
A. Kotlyar,
J. F. Kukowska-Latallo,
A. Bielinska,
A. Myc, J. R. Baker Jr.,
“Targeting and inhibition of cell growth by an engineered dendritic nanodevice,”
J. Med. Chem., 48
(11), 3729
–3735
(2005). 0022-2623 Google Scholar
J. Y. Ye,
T. P. Thomas,
M. T. Myaing, J. R. Baker Jr., T. B. Norris,
“Biosensing based on two-photon fluorescence measurements through optical fibers,”
Opt. Lett., 27 1412
–1414
(2002). 0146-9592 Google Scholar
J. F. Kukowska-Latallo,
K. A. Candido,
Z. Cao,
S. S. Nigavekar,
I. J. Majoros,
T. P. Thomas,
L. P. Balogh,
M. K. Khan, J. R. Baker Jr.,
“Nanoparticle targeting of anticancer drug improves therapeutic response in animal model of human epithelial cancer,”
Cancer Res., 65
(12), 5317
–5324
(2005). https://doi.org/10.1158/0008-5472.CAN-04-3921 0008-5472 Google Scholar
|