Frequency-division multiplexing (FDM) technologies are being developed for HUBS, which contains over 3000 transition-edge sensor (TES) microcalorimeters with an energy resolution of 2 eV (@0.6 keV). As a first step, an FDM system is designed and implemented for its pathfinder (DIXE), which employs a 10x10 TES microcalorimeter array, achieving an energy resolution of 6 eV or better over an energy range from 0.1 to 10 keV. The system has a multiplexing factor of 40 within the 1-5 MHz bandwidth. The warm electronics features a Kintex-7 FPGA and Magnicon Low-Noise Amplifier (LNA), coupled with baseband feedback software. Substantial progress has also been made on the cold electronics, with LC filters fabricated to achieve a 2 μm line width of the superconducting inductor and a dielectric constant of 11 for the capacitor. Superconducting Quantum Interference Devices (SQUIDs) have been fabricated, with the readout noise measured to be less than 6 pA/ √ Hz. This report presents the initial design both on the warm electronics and the superconducting circuit, offering an overview of the progress made. The findings support the conceptual viability of employing FDM for the multiplexed readout of TES microcalorimeters in the context of HUBS.
The Hot Universe Baryon Surveyor (HUBS) is a proposed X-ray satellite project dedicated to addressing the “missing baryon problem”. Its payload incorporates transition-edge sensor (TES) microcalorimeters operating at sub-100 mK, making adiabatic demagnetization refrigerator (ADR) a key technology for the HUBS mission. Currently, we are in the process of improving the performance of a two-stage ADR prototype, mainly to increase the hold time at the operating temperature. We replace the previous chromium potassium alum (CPA) salt pill with a new ferric ammonium alum (FAA) salt pill containing more moles of crystals, as FAA has more cooling capacity than CPA per mole in the temperature range of interest. In this paper, we describe the performance improvement of the ADR prototype and present the test results.
The Hot Universe Baryon Surveyor (HUBS) is a satellite mission that is proposed to probe “hidden” baryons in the universe and thus to fill a void in observational astronomy that seriously affects our understand of galaxy formation and evolution. The HUBS payload is highly optimized for detecting diffuse X-ray emission from the baryons, with the combination of large field of view and high spectral resolution. To assess the scientific capabilities of HUBS, we created mock observations with data from a state-of-the-art cosmological hydrodynamical simulation (IllustrisTNG). The targets include systems that are representative of galaxies, galaxy groups, and galaxy clusters at various redshifts. We generated the X-ray spectra and images of the selected sources from the mock observations, taking into account galactic foreground emission, X-ray emission from cosmologically distant background sources, as well as emission from other sources along the lines of sight. The results from analyzing the mock observations show that the assumed design of HUBS is appropriate for achieving its primary scientific objectives. In this paper, we present the results and discuss issues related to observing strategies.
In the area of space astronomy, some electronic detectors should be cooled to liquid helium temperature level to improve their sensitivity and reduce the background noise. A hybrid J-T cooler has been developed for future space application by our laboratory. The J-T loop is precooled by two-stage thermally coupled pulse tube cooler. There is no moving part at low temperature in this system which features low vibration electromagnetic interference. The hybrid J-T cooler has been experimental tested and cooling capacity of about 34.5mW@4.32K is achieved when supply pressure is 1.97MPa. Besides, when sufficient precooling power is provided for the J-T loop cooling capacity of 102.3mW at 5.02K is achieved. In this experiment, three oil free linear compressors are used to drive the J-T loop and a GM cooler is used to provide the precooling power for the J-T cooler. This J-T cooler will be the potential cryocooler for the future space detectors requiring cooling power of 100mW at < 6K.
Transition Edge Sensor (TES) is a key component for Hot Universe Baryon Survey (HUBS), which is proposed in China to address the so-called “missing baryon problem”. A stable heat sink below 100 mK is needed for the detector’s noise suppression and high resolution. Since HUBS is a satellite based observation mission, a complicated cooling system suitable for space application becomes an important supporting sub-system. A compounded cooling system, including a mechanical cryocooler and an adiabatic magnetization refrigerator (ADR), has been proposed for HUBS. The mechanical cryocooler is used as the pre-cooling 4 K stage, and the ADR is responsible for further reducing the temperature to below 100 mK. High-frequency pulse tube cryocooler (HPTC) and HPTC combined with Joule Thompson cooler (J-T) are two candidates for the mechanical pre-cooling stage, both of which are currently under development. The ADR is being designed and processed. In this paper, we will present the preliminary architecture of the HUBS cooling system, as well as the latest states of HPTC, J-T, and ADR.
The high-resolution X-ray imaging spectrometer of the Hot Universe Baryon Surveyor (HUBS) mission is based on the superconducting transition edge sensor (TES) technology. A TES serves as a thermometer for sensing the temperature change of a microcalorimeter to measure the energy of incident X-rays. In order to achieve high sensitivity, TES needs to operate at temperatures below 100 mK. A combination of a 4 K pre-cooling system and a sub-K cooling system is required to achieve such a low temperature. In this paper, it is proposed to directly obtain the 4 K temperature by a high frequency pulse tube cryocooler (HPTC) for HUBS. The advantages of this technology is compact structure and high reliability, compared with other technologies (for instance, multi-stage Stirling cryocoolers + Joule-Thompson cooler). We have constructed a multi-stage HPTC. The test cooling performance, as well as the design of the cryocooler, existing challenges and proposed solutions will be presented.
The Hot Universe Baryon Surveyor (HUBS) is a satellite concept proposed in China to address the so-called “missing baryon problem”, which has serious implications on the formation and evolution of galaxies. At the heart of HUBS there is a high-resolution soft X Ray spectrometer based on transition-edge sensors operating below 100 mK. A cooling system is needed to provide such a low-temperature environment. It necessarily consists of a precooling stage and a cold stage. The cold stage could be enabled by an adiabatic demagnetization refrigerator (ADR). Because an ADR could be operated without gravity’s assist and has no refrigerant consumption, it is a good candidate for satellite mission like HUBS. For HUBS, the ADR will be employed to cool the detector down to below 100 mK from the precooling stage (at about 4K), which is enabled by mechanical pulse tube refrigerators. ADR for HUBS is now under development in our lab. The key technologies of building an ADR including growth of paramagnetic salt pill crystals, gas-gap heat switch are under development. A preliminary design of the ADR is completed and the design parameters are optimized. In this paper, we report on the status of the development.
Hot Universe Baryon Surveyor (HUBS)1 is being conceptualized in China as a high throughput and highresolution spectroscopic X-ray mission dedicated to studying cosmic “missing” baryons, which are thought to exist in the gas of very low density and temperature of roughly one million degrees in the halo of galaxies or in large-scale structures. To detect weak emission from the “missing” baryons, HUBS will employ an X-ray microcalorimeter based on transition-edge sensors (TES) array that operates at very low temperatures. The key characteristics of the detector technology are excellent energy resolution and high quantum efficiency, which makes it an ideal choice for constructing a non-dispersive X-ray imaging spectrometer. We are developing X-ray microcalorimeters for HUBS, based on superconducting Mo/Cu bilayer films. In this work, we present results on characterization of the Mo/Cu films and TES devices at temperatures below 200 mK, including their I − V characteristics, pulse signals and energy resolutions. We have also studied correlations between the superconductivity and other properties of the films (including residual resistivity ratio, stress, crystalline structure, interface properties, etc.). Preliminary results are presented in this work.
The Hot Universe Baryon Surveyor (HUBS) mission is proposed to study “missing” baryons in the universe. Unlike dark matter, baryonic matter is made of elements in the periodic table, and can be directly observed through the electromagnetic signals that it produces. Stars contain only a tiny fraction of the baryonic matter known to be present in the universe. Additional baryons are found to be in diffuse (gaseous) form, in or between galaxies, but a significant fraction has not yet been seen. The latter (“missing” baryons) are thought to be hiding in low-density warm-hot ionized medium (WHIM), based on results from theoretical studies and recent observations, and be distributed in the vicinity of galaxies (i.e., circumgalactic medium) and between galaxies (i.e., intergalactic medium). Such gas would radiate mainly in the soft X-ray band and the emission would be very weak, due to its very low density. HUBS is optimized to detect the X-ray emission from the hot baryons in the circumgalactic medium, and thus fill a void in observational astronomy. The goal is not only to detect the “missing” baryons, but to characterize their physical and chemical properties, as well as to measure their spatial distribution. The results would establish the boundary conditions for understanding galaxy evolution. Though highly challenging, detecting “missing” baryons in the intergalactic medium could be attempted, perhaps in the outskirts of galaxy clusters, and could shed significant light on the large-scale structures of the universe. The current design of HUBS will be presented, along with the status of technology development.
Hot Universe Baryon Surveyor (HUBS) is being conceptualized in China as a high throughput and high-resolution spectroscopic X-ray mission dedicated to studying cosmic "missing" baryons, which are thought to exist in the gas of very low density and temperature roughly one million degrees in the halo of galaxies or in large-scale structures. To detect weak emission from the "missing" baryons, HUBS will employ a TES-based X-ray microcalorimeter array that operates at very low temperatures. The key characteristics of the detector technology are excellent energy resolution and high quantum efficiency, which makes it an ideal choice for constructing a non-dispersive X-ray imaging spectrometer. We are developing X-ray microcalorimeters for HUBS, based on superconducting Mo/Cu bilayer films. In this work, we present results on the characterization of the Mo/Cu films and TES devices at temperatures below 100 mK, including their R-T curves, I-V characteristics, energy resolutions, etc. We have also studied correlations between the superconducting transition temperature and other properties of the films (including residual resistivity ratio, stress, crystalline structure, interface properties, and so on), and looked into factors that might affect the energy resolution of the detectors. Preliminary results will be presented.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
INSTITUTIONAL Select your institution to access the SPIE Digital Library.
PERSONAL Sign in with your SPIE account to access your personal subscriptions or to use specific features such as save to my library, sign up for alerts, save searches, etc.