The NIRSpec instrument for the James Webb Space Telescope (JWST) is a highly versatile near-infrared spectrograph that can be operated in various observing modes, slit apertures, and spectral resolutions. Obtaining dedicated calibration data for all possible combinations of aperture and disperser is an intractable task. We have therefore developed a procedure to derive a highly realistic model of the instrument’s optical geometry across the entire field of view, using calibration data acquired through only a subset of NIRSpec apertures, which nevertheless allows the light paths within the spectrograph to be accurately computed for all apertures and all observing modes. This parametric instrument model thus provides the basis for the extraction of wavelengthcalibrated spectra from any NIRSpec exposure, regardless of observing mode or aperture used. Optimizing the NIRSpec instrument model and deriving its final wavelength and astrometric calibration was one of the most crucial elements of the NIRSpec commissioning phase. Here, we describe the process of re-fitting the NIRSpec instrument model with in-orbit commissioning data, and present its final performance in terms of wavelength accuracy and astrometric calibration.
The NIRSpec instrument on the James Webb Space Telescope (JWST) brings the first multi-object spectrograph (MOS) into space, enabled by a programmable Micro Shutter Array (MSA) of ∼250,000 individual apertures. During the 6-month Commissioning period, the MSA performed admirably, completing ∼800 reconfigurations with an average success rate of ∼96% for commanding shutters open in science-like patterns. We show that 82.5% of the unvignetted shutter population is usable for science, with electrical short masking now the primary cause of inoperable apertures. In response, we propose a plan to recheck existing shorts during nominal operations, which is expected to reduce the number of affected shutters. We also present a full assessment of the Failed Open and Failed Closed shutter populations, which both show a marginal increase in line with predictions from ground testing. We suggest an amendment to the Failed Closed shutter flagging scheme to improve flexibility for MSA configuration planning. Overall, the NIRSpec MSA performed very well during Commissioning, and the MOS mode was declared ready for science operations on schedule.
The Near-Infrared Spectrograph (NIRSpec) is one of the four focal plane instruments on the James Webb Space Telescope which was launched on Dec. 25, 2021. We present an overview of the as-run NIRSpec commissioning campaign, with particular emphasis on the sequence of activities that led to the verification of all hardware components of NIRSpec. We also discuss the mechanical, thermal, and operational performance of NIRSpec, as well as the readiness of all NIRSpec observing modes for use in the upcoming JWST science program.
KEYWORDS: Iterated function systems, Sensors, Photons, James Webb Space Telescope, Telescopes, Instrument modeling, Point spread functions, Calibration, Near infrared spectroscopy
To achieve its ambitious scientific goals, the Near-Infrared Spectrograph, NIRSpec, on board the Webb Space Telescope, needs to meet very demanding throughput requirements, here quantified in terms of photon-conversion efficiency (PCE). During the calibration activities performed for the instrument commissioning, we have obtained the first in-flight measurements of its PCE and also updated the modeling of the light losses occurring in the NIRSpec slit devices. The measured PCE of NIRSpec fixed-slit and multi-object spectroscopy modes overall meets or exceeds the pre-launch model predictions. The results are more contrasted for the integral-field spectroscopy mode, where the differences with the model can reach −20%, above 4 μm, and exceed +30%, below 2 μm. Additionally, thanks to the high quality of the JWST point-spread function, our slit-losses, at the shorter wavelength, are significantly decreased with respect to the pre-flight modeling. These results, combined with the confirmed low noise performance of the detectors, make of NIRSpec an exceptionally sensitive spectrograph.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
INSTITUTIONAL Select your institution to access the SPIE Digital Library.
PERSONAL Sign in with your SPIE account to access your personal subscriptions or to use specific features such as save to my library, sign up for alerts, save searches, etc.