Paper
16 June 2005 Actual measurement data obtained on new 65nm generation mask metrology tool set
Jochen Bender, Michael Ferber, Klaus-Dieter Roth, Gerhard Schluter, Walter Steinberg, Gerd Scheuring, Frank Hillmann
Author Affiliations +
Proceedings Volume 5835, 21st European Mask and Lithography Conference; (2005) https://doi.org/10.1117/12.637319
Event: 21st European Mask and Lithography Conference, 2005, Dresden, Germany
Abstract
For 65nm photo mask lithography, metrology becomes significantly more important. Especially the requirements of the photo mask users versus critical dimension (CD) control, CD homogeneity and CD mean to target, give strong head-aches to lithography and process control engineers. Despite the fact that optical CD metrology has limitations versus resolution it still provides valuable information since measurement takes place in transmission similar to the application of the mask during printing to the wafer. The optical resolution should at least support to measure minimum features of 250nm on the masks in the linear regime. In order to qualify structure fidelity and width of assist structures and small contact holes as well as certain OPC pattern which are usually smaller than the limits of optical measurement capability, actually CD SEM systems are recognized as the tool of choice to qualify the reticles. No matter which kind of CD metrology tool is used, long-term repeatability over several days must be below 1nm (3 sigma). This paper will show measurement performance data on two types of reticle CD measurement systems targeting the 65nm node reticles. Another issue of high importance is pattern placement or registration metrology on reticles. Roadmaps of leading edge mask users request a maximum placement error of less than 13nm for the 65nm technology node. This strong require-ment challenges the control of the mask lithography tool and the long-term repeatability of the registration metrology system must not exceed 2.5nm. This paper summarizes the actual performance of Leica's mask metrology tool set and the improvements on the individ-ual systems leading to the respective performance.
© (2005) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Jochen Bender, Michael Ferber, Klaus-Dieter Roth, Gerhard Schluter, Walter Steinberg, Gerd Scheuring, and Frank Hillmann "Actual measurement data obtained on new 65nm generation mask metrology tool set", Proc. SPIE 5835, 21st European Mask and Lithography Conference, (16 June 2005); https://doi.org/10.1117/12.637319
Lens.org Logo
CITATIONS
Cited by 2 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Scanning electron microscopy

Photomasks

Reticles

Critical dimension metrology

Metrology

Contamination

Optical testing

RELATED CONTENT

New process monitor for reticles and wafers the MEEF...
Proceedings of SPIE (June 02 2000)
Aging study in advanced photomasks impact of EFM effects...
Proceedings of SPIE (September 24 2010)
Next-generation mask metrology tool
Proceedings of SPIE (August 01 2002)
Reticle CD-SEM for 65-nm technology node and beyond
Proceedings of SPIE (December 06 2004)

Back to Top