At the moment, percutaneous needle biopsy (PNB) remains the gold standard for diagnosing liver cancer. However, the relatively high probability of false-negative results can still be an issue with the method. The introduction of real-time feedback for the precise navigation of the biopsy tool is an up-and-coming technology to immensely reduce the mistakes in taking relevant tissue samples. This work presents the technical details of the developed optical biopsy system, which implements fluorescence lifetime and diffuse reflectance measurements. Also, we demonstrate the most recent results of measurements by the system equipped with a novel needle optical probe, compatible with the 17.5G biopsy needle standard. At the first stage, measurements were verified in the murine model with inoculated hepatocellular carcinoma (HCC). With that model, we demonstrate that the registered set of independent diagnostic parameters allows us to reliably distinguish the HCC tissue, liver tissue in the control and the metabolically changed liver tissues of animals with the developed HCC tumour. At the second stage, the optical biopsy system was tested during the routing procedure of the transcutaneous biopsy in humans with suspected cancerous processes in the liver. Our results demonstrate that the developed technique can reliably discriminate malignant tumours of different nature (primary HCC and adenocarcinoma metastasis) from liver tissues. We conclude that, being supported by machine learning approaches, the presented technique can significantly decrease the rate of false-negative results for transcutaneous biopsy.
This article describes the results of experimental studies using optical methods for in vitro estimation of the composition of bile obtained from patients with different etiologies of obstructive jaundice. Experimental studies were carried out using spectrophotometry and Raman spectroscopy methods to study and compare optical properties of bile from patients with obstructive jaundice caused either by choledocholithiasis or malignant tumors. The results show that the selected methods are suitable for studying the composition and optical properties of bile and can provide additional diagnostic information. Averaged Raman spectra, as well as absorption spectra of bile, corresponding to different etiologies of jaundice origin were demonstrated.
To determine optimal lighting conditions for contrast imaging of surgical objects, optical characteristics of biological tissues and spectral characteristics of smart light "LED light" source based on RGBW LED are compared. The spectral characteristics of tissues and organs have been investigated. Optimal lighting conditions for contrast imaging of biological tissues during surgery were studied. The optimal colour of light for working with individual organs against the background of the whole organism is selected. Perspective of light fixture application with the possibility of dynamic colour control is shown.
Liposomal particles are used as an instrument for drug delivery and as fluorescent labels. Due to its properties, liposomal particles can be used as a dual-purpose contrast agent both in fluorescence imaging, laser speckle contrast imaging and ultrasound diagnostics. Liposomes obtained by one purpose but subsequently contained a fluorescent label or air. This work aimed to prepare liposomal particles and to study possibilities of its application for the dual-use in fluorescence spectroscopy and ultrasound diagnostics. In this work, we used fluorescence spectroscopy to investigate the efficiency of propagation in the circulatory system of fluorescent-labelled liposome nanocapsules loaded with eosin-Y (disodium salt of 2,4,5,7 tetrabromofluorescein These results demonstrate that liposomal particles can be used in fluorescence spectroscopy, in ultrasound diagnostics and in LSCI. It may find the application in the field of drug delivery control and high-throughput screening during drug development.
The paper describes the results of experimental studies using custom developed optical biopsy system for diagnostics in vivo during the procedure of fine needle aspiration biopsy. Experimental studies were conducted in laboratory mice with inoculated hepatocellular carcinoma. The measurements were carried out using fluorescence spectroscopy and diffuse reflectance spectroscopy methods to reveal metabolic and morphological changes in tissues. The results show that the developed approach is sensitive for cancer detection. Quantified differences in the maximum of fluorescence spectra and diffuse reflectance spectra between tumor and normal tissues were demonstrated and approved with morphological analysis.
The paper describes the methodology and technical implementation of a multimodal approach for optical diagnostics in hepatopancreatobiliary organs focal and diffuse neoplasms. Fine needle aspiration biopsy technique and following cytological examination show its effectiveness and safety but its performing takes several days. However, the problem of real-time analysis of pathological changes in tissues remains relevant. The solution suggested is implementing of optical biopsy methods (namely fluorescence spectroscopy and diffuse reflectance spectroscopy) in the form of fiber-optic probe compatible with standard biopsy fine needles. The special device was designed for this purpose to conduct optical measurements and compare the results with ones obtained by conventional biopsy. The proposed methodology seems promising for developing new diagnostic criteria for clinical practice.
Diagnosis and treatment of acute destructive pancreatitis is one of the most urgent problems of abdominal surgery. To obtain additional diagnostic information about the microcirculation state and metabolic processes, various imaging techniques are widely used during surgical interventions. One of the most perspective techniques for in vivo microcirculation assessment is laser speckle-contrast imaging (LSCI), allowing for evaluation of blood perfusion. The experimental results showed the possibility to evaluate the blood perfusion of the mouse pancreas in the simulation of ischemia using the LSCI method.
The paper presents the results of in vivo experimental measurements of the endogenous fluorescence and blood perfusion in common bile duct tissues in obstructive jaundice patients during minimally invasive surgical operations. Nowadays the type of interventions become more widespread for treating hepatopancreatobiliary pathologies. An effective feedback which can be established by one or more optical diagnostic channels integrated into the standard instruments for minimally invasive manipulations would be of particular value to practical surgeons. To collect reference data, an experimental study has been conducted using a fiber optical probe with fluorescence spectroscopy and laser Doppler flowmetry channels. For every measurement, the areas of interest were different areas of common bile duct obstructed by a malignant tumor. Obtained results demonstrated significant variety registered intensities of fluorescence spectra and values of blood perfusion. Tested fiber optical endoscopic system showed sensitivity to the tissue state in the investigated area, so the two modal approach seems to be promising for further research and implementation in clinical practice.
Fine needle aspiration biopsy technique and following histological examination show its effectiveness and safety but its performing takes several time. However, the problem of real-time analysis of pathological changes in tissues remains relevant. We demonstrate optical fine-needle biopsy method, combining a fine needle (17.5G) and a fiber-optic probe (1 mm diameter) for minimally invasive interrogation of tissue in vivo. During rat tumor experiment, we collected spectrally-resolved diffuse reflectance and fluorescence. Quantified differences between tumor and normal tissues were demonstrated and approved with morphological analysis. The proposed methodology seems promising for developing new diagnostic criteria for clinical practice.
At present, minimally invasive interventions become more widespread for treating hepatopancreatoduodenal area pathologies. However, new methods and approaches are necessary for obtaining more diagnostic information in real time. Several methods within the framework of “optical biopsy” concept are considered. The features and areas of application of each method are reviewed to find out which of them can be used in further studies to assess the possibility of intraoperative use in minimally invasive abdominal surgery. Preliminary measurements with fluorescence spectroscopy method have been performed at excitation wavelengths 365 nm and 450 nm. Areas of interest were common bile duct, gallbladder and liver abscess. In our opinion, the obtained results can be a basis for further research and provide a deeper understanding of pathological processes of abdominal cavity organs tissues.
The studies were carried out on groups of clinically healthy mice line of outbred CD-1 stock. The model animals were divided into 2 groups and received experimental liposomal formulations. Using the method of fluorescence spectroscopy, we investigated the effectiveness of penetration into the circulatory system of fluorescently stained liposomes with polyethylene glycol (PEG) and without PEG when administered orally. Fluorescence channel with a fiber probe series of multifunctional laser non-invasive diagnostic system “LAKK-M” (SPE “LAZMA” Ltd, Russia) was used as the measuring equipment.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
INSTITUTIONAL Select your institution to access the SPIE Digital Library.
PERSONAL Sign in with your SPIE account to access your personal subscriptions or to use specific features such as save to my library, sign up for alerts, save searches, etc.