The Space Infrared Telescope for Cosmology and Astrophysics (SPICA) mission is to be launched into orbit around the second Lagrangian point (L2) in the Sun-Earth system. Taking advantage of the thermal environment in L2, a 2.5m-class large IR telescope is cooled below 8K in combination with effective radiant cooling and a mechanical cooling system. SPICA adopts a cryogen-free system to prevent the mission operation lifetime being limited by the amount of cryogen as a refrigerant. Currently, the mechanical cooler system with the feasible solution giving a proper margin is proposed. As a baseline design, 4K / 1K-class Joule-Thomson coolers are used to cool the telescope and thermal interface for Focal Plane Instruments (FPIs). Additionally, two sets of double stage stirling coolers (2STs) are used to cool the telescope shield. In this design, nominal operation of FPIs can be kept when one mechanical cooler is in failure. In this paper, current baseline configuration of the mechanical cooler system and current status of mechanical coolers developments which need to satisfy the specific requirements of SPICA cryogenic system are presented.
KEYWORDS: Sensors, Frequency modulation, Temperature metrology, Cryocoolers, Vibration isolation, X-rays, Space operations, Spectroscopy, Fermium, Head
The soft x-ray spectrometer (SXS) onboard ASTRO-H (named Hitomi after launch) is a microcalorimeter-type spectrometer, installed in a dewar to be cooled at 50 mK. The energy resolution of the SXS engineering model suffered from microvibration from cryocoolers mounted on the dewar. This is mitigated for the flight model (FM) by introducing vibration isolation systems between the cryocoolers and the dewar. The detector performance of the FM was verified before launch of the spacecraft in both ambient condition and thermal-vacuum condition, showing no detectable degradation in energy resolution. The in-orbit detector spectral performance and cryocooler cooling performance were also consistent with that on ground, indicating that the cryocoolers were not damaged by launch environment. The design and performance of the vibration isolation system along with the mechanism of how the microvibration could degrade the cryogenic detector is shown. Lessons learned from the development to mitigate unexpected issues are also described.
The soft x-ray spectrometer (SXS) was a cryogenic high-resolution x-ray spectrometer onboard the Hitomi (ASTRO-H) satellite that achieved energy resolution of 5 eV at 6 keV, by operating the detector array at 50 mK using an adiabatic demagnetization refrigerator (ADR). The cooling chain from room temperature to the ADR heat sink was composed of two-stage Stirling cryocoolers, a He4 Joule–Thomson cryocooler, and superfluid liquid helium and was installed in a dewar. It was designed to achieve a helium lifetime of more than 3 years with a minimum of 30 L. The satellite was launched on February 17, 2016, and the SXS worked perfectly in orbit, until March 26 when the satellite lost its function. It was demonstrated that the heat load on the helium tank was about 0.7 mW, which would have satisfied the lifetime requirement. This paper describes the design, results of ground performance tests, prelaunch operations, and initial operation and performance in orbit of the flight dewar and the cryocoolers.
When using superfluid helium in low-gravity environments, porous plug phase separators are commonly used to vent boil-off gas while confining the bulk liquid to the tank. Invariably, there is a flow of superfluid film from the perimeter of the porous plug down the vent line. For the soft x-ray spectrometer onboard ASTRO-H (Hitomi), its approximately 30-liter helium supply has a lifetime requirement of more than 3 years. A nominal vent rate is estimated as ∼30 μg/s, equivalent to ∼0.7 mW heat load. It is, therefore, critical to suppress any film flow whose evaporation would not provide direct cooling of the remaining liquid helium. That is, the porous plug vent system must be designed to both minimize film flow and to ensure maximum extraction of latent heat from the film. The design goal for Hitomi is to reduce the film flow losses to <2 μg/s, corresponding to a loss of cooling capacity of <40 μW. The design adopts the same general design as implemented for Astro-E and E2, using a vent system composed of a porous plug, combined with an orifice, a heat exchanger, and knife-edge devices. Design, on-ground testing results, and in-orbit performance are described.
The Soft X-ray Spectrometer (SXS) is a cryogenic high-resolution X-ray spectrometer onboard the ASTRO-H satellite, that achieves energy resolution better than 7 eV at 6 keV, by operating the detector array at 50 mK using an adiabatic demagnetization refrigerator. The cooling chain from room temperature to the ADR heat sink is composed of 2-stage Stirling cryocoolers, a 4He Joule-Thomson cryocooler, and super uid liquid He, and is installed in a dewar. It is designed to achieve a helium lifetime of more than 3 years with a minimum of 30 liters. The satellite was launched on 2016 February 17, and the SXS worked perfectly in orbit, until March 26 when the satellite lost its function. It was demonstrated that the heat load on the He tank was about 0.7 mW, which would have satisfied the lifetime requirement. This paper describes the design, results of ground performance tests, prelaunch operations, and initial operation and performance in orbit of the flight dewar and cryocoolers.
Suppression of super fluid helium flow is critical for the Soft X-ray Spectrometer onboard ASTRO-H (Hitomi). In nominal operation, a small helium gas flow of ~30 μg/s must be safely vented and a super fluid film flow must be sufficiently small <2 μg/s. To achieve a life time of the liquid helium, a porous plug phase separator and a film flow suppression system composed of an orifice, a heat exchanger, and knife edge devices are employed. In this paper, design, on-ground testing results and in-orbit performance of the porous plug and the film flow suppression system are described.
KEYWORDS: Vibration isolation, Sensors, Cryocoolers, X-rays, Spectroscopy, X-rays, Space operations, Temperature metrology, Fermium, Frequency modulation, Head
Soft X-ray Spectrometer (SXS) onboard ASTRO-H (named Hitomi after launch) is a microcalorimeter-type spectrometer, installed in a dewar to be cooled at 50 mK. The energy resolution of the SXS engineering model suffered from micro-vibration from cryocoolers mounted on the dewar. This is mitigated for the flight model by introducing vibration isolation systems between the cryocoolers and the dewar. The detector performance of the flight model was verified before launch of the spacecraft in both ambient condition and thermal-vac condition, showing no detectable degradation in energy resolution. The in-orbit performance was also consistent with that on ground, indicating that the cryocoolers were not damaged by launch environment. The design and performance of the vibration isolation system along with the mechanism of how the micro-vibration could degrade the cryogenic detector is shown.
Sumitomo Heavy Industries, ltd. (SHI) has been developing cooler and Dewar technology for space application with
Japan Aerospace Exploration Agency. SHI has four types of coolers to cover temperature range from 1.7K to 80K or
more. Those are Single stage Stirling coolers for 80K, two-stage Stirling coolers for 20K, 4K-class cooler and 1K-class
cooler. 4K and 1K class coolers consist of a Joule-Thomson cooler and a two-stage Stirling as a pre-cooler. SHI also
provided Dewars. In this paper, SHI’s cooler and Dewar technology are described.
The conceptual design of the Space Infrared Telescope for Cosmology and Astrophysics (SPICA) has been studied as a
pre-project of the Japan Aerospace Exploration Agency (JAXA) in collaboration with ESA to be launched in 2018. The
SPICA is transferred into a halo orbit around the second Lagrangian point in the Sun-Earth system, where radiant
cooling is available effectively. The SPICA has a large IR telescope 3 m in diameter, which is cooled without cryogen to
below 6 K by the radiant and mechanical cooling system. Therefore, the SPICA mission will cover mid- and far-IR
astronomy with high sensitivity and spatial resolution during a long period of over 5 years for goal. Most heat radiation
from the sun and spacecraft is blocked by the Sun Shield and thermal radiation shields covered with Multi-Layer
Insulator (MLI) to limit heat radiation to the Scientific Instrument Assembly (SIA). The SIA, which is composed of the
primary mirrors and optical benches equipped with Focal Plane Instruments (FPIs), is refrigerated to below 6 K by two
sets of 4K-class Joule-Thomson (JT) cooler with a cooling power of 40 mW at 4.5 K. The Far-IR detector is refrigerated
to 1.7 K by two sets of 1K-class JT coolers with a cooling power of 10 mW at 1.7 K. Improvements for the higher
reliability and sufficient cooling performance are required in the development of SPICA mechanical cryocoolers.
Thermal analysis indicates that the SPICA cryogenic system works effectively to limit the total heat load on the SIA to
41.2 mW. This paper describes the conceptual design of the SPICA cryogenic system, which was established with
thermal feasibility for nominal operation mode.
The Soft X-ray Spectrometer (SXS) is a cryogenic high resolution X-ray spectrometer onboard the X-ray astronomy
satellite ASTRO-H. The detector array is cooled down to 50 mK using a 3-stage adiabatic demagnetization
refrigerator (ADR). The cooling chain from room temperature to the ADR heat-sink is composed of superfluid
liquid He, a 4He Joule-Thomson cryocooler, and 2-stage Stirling cryocoolers. It is designed to keep 30 L of liquid
He for more than 3 years in the nominal case. It is also designed with redundant subsystems throughout from
room temperature to the ADR heat-sink, to alleviate failure of a single cryocooler or loss of liquid He.
The SXS (Soft X-ray Spectrometer) onboard the coming Japanese X-ray satellite NeXT (New Exploration Xray
Telescope) and the SXC (Spectrum-RG X-ray Calorimeter) in Spectrum-RG mission are microcalorimeter
array spectrometers which will achieve high spectral resolution of ~ 6 eV in 0.3-10.0 keV energy band. These
spectrometers are well-suited to address key problems in high-energy astrophysics. To achieve these high spectral
sensitivities, these detectors require to be operated under 50 mK by using very efficient cooling systems including
adiabatic demagnetization refrigerator (ADR). For both missions, we propose a two-stage series ADR as a cooling
system below 1 K, in which two units of ADR consists of magnetic cooling material, a superconducting magnet,
and a heat switch are operated step by step. Three designs of the ADR are proposed for SXS/SXC. In all three
designs, ADR can attain the required hold time of 23 hours at 50 mK and cooling power of 0.4μW with a low
magnetic fields (1.5/1.5 Tesla or 2.0/3.0 Tesla) in a small configuration (180 mmφ× 319 mm in length).
We also fabricated a new portable refrigerator for a technology investigation of two-stage ADR. Two units of
ADR have been installed at the bottom of liquid He tank. By using this dewar, important technologies such as an operation of two-stage cooling cycle, tight temperature control less than 1 μK (in rms) stability, a magnetic
shielding, saltpills, and gas-gap heat switches are evaluated.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
INSTITUTIONAL Select your institution to access the SPIE Digital Library.
PERSONAL Sign in with your SPIE account to access your personal subscriptions or to use specific features such as save to my library, sign up for alerts, save searches, etc.