In the leading-edge production measuring the geometrical dimensions with e-beam inspection (CD-SEM data) or scatterometry technology (OCD data) is one of the most time-consuming steps without adding value to the wafer. Hence the fabs want to limit the effort to minimize the costs per wafer. On the other hand, the output of the metrology steps is needed to feed the SPC and APC systems with sufficient information. We handle that trade-off with a new sampling scheme optimizer supporting CD-SEM and OCD data.
Generally, we can use the sampling scheme optimization for a set of different features and their measured parameters in parallel. Especially in logic, but also for memory, the focus and dose dependencies of several features may be different. Hence, we optimized the distribution of the measured sites to create a perfect representation of the systematic fingerprint for all important anchor features within one single sampling scheme.
For the verification of the approach we investigated two cases. The first case are dense CD measurements, which are usually needed to create and update intra-field dose corrections. We minimize the number of measured sites significantly and distribute the remaining sites over different fields to ensure a good coverage of the systematic effects. Finally, that allows us a much higher update frequency of the dose corrections and yields in smaller CDU values.
The second case optimized the throughput of an OCD metrology system. The applied high-density sampling scheme for the focus monitoring done on reference wafers takes a lot of time during measuring. That specific type of measurement is done for monitoring and updating the focus reference corrections. With our proposed solution, we can achieve the same quality with respect to the reference measurement with more 50% less measured sites.
Overlay process control is a critical aspect of integrated circuit manufacturing. Advanced DRAM manufacturing overlay error budget approaches the sub-2nm threshold, including all sources of overlay error: litho processing, non-litho processing, metrology error, etc. Overlay measurement quality, both for accuracy and robustness, depends on the metrology system and its recipe setup. The optimal configuration depends on the layer and materials involved. Increased flexibility of metrology setup is of paramount importance, paired with improved methods of recipe optimization.
Both optical image-based overlay (IBO) and scatterometry diffraction overlay (SCOL®) are necessary tools for overlay control. For some devices and layers IBO provides the best accuracy and robustness, while on others SCOL provides optimum metrology. Historically, wavelength selection was limited to discrete wavelengths and at only a single wavelength. At advanced nodes IBO and SCOL require wavelength tunability and multiple wavelengths to optimize accuracy and robustness, as well as options for polarization and numerical aperture (NA). In previous studies1,2,3 we investigated wavelength tunability analysis with landscape analysis, using analytic techniques to determine the optimal setup. In this report we show advancements in the landscape analysis technique for IBO through both focus and wavelength, and comparisons to SCOL. A key advantage of imaging is the ability to optimize wavelength on a per-layer basis. This can be a benefit for EUV layers in combination with those of 193i, for example, as well as other applications such as thick 3D NAND layers. The goal is to make accurate and robust overlay metrology that is immune from process stack variations, and to provide metrics that indicate the quality of metrology performance. Through both simulation and on-wafer advanced DRAM measurements, we show quantitative benefits of accuracy and robustness to process stack variability for IBO and SCOL applications.
Methodologies described in this work can be achieved using Archer™ overlay metrology systems, ATL™ overlay metrology systems, and 5D Analyzer® advanced data analysis and patterning control solution.
In overlay (OVL) metrology the quality of measurements and the resulting reported values depend heavily on the measurement setup used. For example, in scatterometry OVL (SCOL) metrology a specific target may be measured with multiple illumination setups, including several apodization options, two possible laser polarizations, and multiple possible laser wavelengths. Not all possible setups are suitable for the metrology method as different setups can yield significantly different performance in terms of the accuracy and robustness of the reported OVL values. Finding an optimal measurement setup requires great flexibility in measurement, to allow for high-resolution landscape mapping (mapping the dependence of OVL, other metrics, and details of pupil images on measurement setup). This can then be followed by a method for analyzing the landscape and selecting an accurate and robust measurement setup. The selection of an optimal measurement setup is complicated by the sensitivity of metrology to variations in the fabrication process (process variations) such as variations in layer thickness or in the properties of target symmetry. The metrology landscape changes with process variations and maintaining optimal performance might require continuous adjustments of the measurement setup. Here we present a method for the selection and adjustment of an optimal measurement setup. First, the landscape is measured and analyzed to calculate theory-based accurate OVL values as well as quality metrics which depend on details of the pupil image. These OVL values and metrics are then used as an internal ruler (“self-reference”), effectively eliminating the need for an external reference such as CD-SEM. Finally, an optimal measurement setup is selected by choosing a setup which yields the same OVL values as the self-reference and is also robust to small changes in the landscape. We present measurements which show how a SCOL landscape changes within wafer, wafer to wafer, and lot to lot with intentionally designed process variations between. In this case the process variations cause large shifts in the SCOL landscape and it is not possible to find a common optimal measurement setup for all wafers. To deal with such process variations we adjust the measurement setup as needed. Initially an optimal setup is chosen based on the first wafer. For subsequent wafers the process stability is continuously monitored. Once large process variations are detected the landscape information is used for selecting a new measurement setup, thereby maintaining optimal accuracy and robustness. Methods described in this work are enabled by the ATL (Accurate Tunable Laser) scatterometry-based overlay metrology system.
KEYWORDS: Semiconducting wafers, Metrology, Critical dimension metrology, Scanners, Process control, Modulation, Scatterometry, Finite element methods, Signal to noise ratio, Single crystal X-ray diffraction
Lithography process control solutions require more exacting capabilities as the semiconductor industry goes forward to the 1x nm node DRAM device manufacturing. In order to continue scaling down the device feature sizes, critical dimension (CD) uniformity requires continuous improvement to meet the required CD error budget. In this study we investigate using optical measurement technology to improve over CD-SEM methods in focus, dose, and CD. One of the key challenges is measuring scanner focus of device patterns. There are focus measurement methods based on specially designed marks on scribe-line, however, one issue of this approach is that it will report focus of scribe line which is potentially different from that of the real device pattern. In addition, scribe-line marks require additional design and troubleshooting steps that add complexity. In this study, we investigated focus measurement directly on the device pattern. Dose control is typically based on using the linear correlation behavior between dose and CD. The noise of CD measurement, based on CD-SEM for example, will not only impact the accuracy, but also will make it difficult to monitor dose signature on product wafers. In this study we will report the direct dose metrology result using an optical metrology system which especially enhances the DUV spectral coverage to improve the signal to noise ratio. CD-SEM is often used to measure CD after the lithography step. This measurement approach has the advantage of easy recipe setup as well as the flexibility to measure critical feature dimensions, however, we observe that CD-SEM metrology has limitations. In this study, we demonstrate within-field CD uniformity improvement through the extraction of clean scanner slit and scan CD behavior by using optical metrology.
As semiconductor manufacturing technology progresses and the dimensions of integrated circuit elements shrink, overlay budget is accordingly being reduced. Overlay budget closely approaches the scale of measurement inaccuracies due to both optical imperfections of the measurement system and the interaction of light with geometrical asymmetries of the measured targets. Measurement inaccuracies can no longer be ignored due to their significant effect on the resulting device yield. In this paper we investigate a new approach for imaging based overlay (IBO) measurements by optimizing accuracy rather than contrast precision, including its effect over the total target performance, using wavelength tunable overlay imaging metrology. We present new accuracy metrics based on theoretical development and present their quality in identifying the measurement accuracy when compared to CD-SEM overlay measurements. The paper presents the theoretical considerations and simulation work, as well as measurement data, for which tunability combined with the new accuracy metrics is shown to improve accuracy performance.
Overlay is one of the most critical process control steps of semiconductor manufacturing technology. A typical advanced scheme includes an overlay feedback loop based on after litho optical imaging overlay metrology on scribeline targets. The after litho control loop typically involves high frequency sampling: every lot or nearly every lot. An after etch overlay metrology step is often included, at a lower sampling frequency, in order to characterize and compensate for bias. The after etch metrology step often involves CD-SEM metrology, in this case in-cell and ondevice. This work explores an alternative approach using spectroscopic ellipsometry (SE) metrology and a machine learning analysis technique. Advanced 1x nm DRAM wafers were prepared, including both nominal (POR) wafers with mean overlay offsets, as well as DOE wafers with intentional across wafer overlay modulation. After litho metrology was measured using optical imaging metrology, as well as after etch metrology using both SE and CD-SEM for comparison. We investigate 2 types of machine learning techniques with SE data: model-less and model-based, showing excellent performance for after etch in-cell on-device overlay metrology.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
INSTITUTIONAL Select your institution to access the SPIE Digital Library.
PERSONAL Sign in with your SPIE account to access your personal subscriptions or to use specific features such as save to my library, sign up for alerts, save searches, etc.